| Model | SC-S03P | |
| Output type | PNP | |
| Type | Obstacle avoidance type | |
| Detection light source | Wavelength 905 nm, Class I laser products | |
| Scanning angle range | 270 | |
| Angular resolution | 0.5 | |
| Measuring accuracy | Standard, ±4 cm@1sigma | |
| Ambient temperature | Work | -10 to +55 °C (no frost and condensation) |
| Storage | -40 to +70 °C | |
| Ambient humidity | Work | 35 to 85 % RH |
| Storage | 35 to 95 % RH | |
| Light interference resistance | 15000 lux | |
| Vibration resistant | Frequency 10 to 55 Hz; Amplitude: 0.35±0.05 mm; Scanning times: three axes, 20 times per axis | |
| Shock resistant | Acceleration 10 g; pulse duration: 16 ms; number of collisions: three axes, 1000±10 per axis | |
| Protection class | IP65 | |
| Dimensions | 80×80×95 mm | |
| Power voltage | DC 9 V to DC 30 V | |
| Power consumption | 5 W (no load on outputs) | |
| Configurable functions | Defense zone configuration | Users can configure the defense zone of SC-S series to the desired shape through the configuration software |
| Response time | 80 ms (2-turn scanning) to 640 ms (16-turn scanning), default 80 ms | |
| Reset function | Configurable for auto or manual reset, default auto reset | |
| External device | Monitor the status of the normally closed contacts of the load when an external relay or contactor load is connected, and the EDM function is disabled by default. | |
| Area group switching | 4 groups of external input signals (Z1, Z2, Z3, Z4) to realize the switching of 16 area groups, default Z1, Z2, Z3, Z4 is not connected when the area group 1 work. | |
| Mounting bracket (sold separately) | Horizontal/vertical/vibration damping/shield mounting optional | |