| Main unit model | TU-H040 | TU-H090 | TU-H160 | TU-H220 | TU-H350 | TU-H600 |
| Type | Diffuse reflective | |||||
| Maximum sensing distance | 400 mm(1) | 900 mm(2) | 1600 mm(2) | 2200 mm(2) | 3500 mm | 6000 mm(2) |
| Minimum sensing distance | 50 mm | 100 mm | 150 mm | 200 mm | 350 mm | 350 mm |
| Sensing range | 50-400 mm | 100-900 mm | 150-1600 mm | 200-2200 mm | 350-3500 mm | 350-6000 mm |
| Beam angle | 10°±2° | 15°±2° | 14°±2° | ±7° | ±9° | |
| Switching frequency (switching output) | 10 Hz | 4 Hz | 3 Hz | 2 Hz | 1 Hz | |
| Response time (switching output) | 500 ms | 250 ms | 500 ms | |||
| Hysteresis | 1 % | |||||
| Repeatability | 0.5 % | 1 % | 0.5 % | |||
| Resolution | ±1 mm | ±2 mm | ±3 mm | ±4 mm | ±6 mm | |
| Linearity error | 1 % | |||||
| Operating temperature range | -20 to +70 °C | |||||
| Temperature compensation | Available | |||||
| Thermal drift | ±2 % | |||||
| Ripple coefficient | 5 % | |||||
| Operating voltage | 12 to 24 VDC | |||||
| Leakage current | 10 µA @ 30 VDC | |||||
| Output voltage drop | 2.2 V max. (I = 100 mA) | |||||
| No-load current | ≤50 mA | |||||
| Output current (switching output) | 100 mA (3) | |||||
| Minimum load resistance (analog voltage output) | 3 kΩ | |||||
| Adjustable switching point | Teach-In button | |||||
| Start-up delay | ≤300 ms | |||||
| Indicator | Green: reflective; Yellow: output | |||||
| Circuit protection | Short-circuit protection (automatic reset), inductive protection, reverse voltage protection | |||||
| Electromagnetic compatibility/EMC | Conforms to the requirements of the EMC directive, in accordance with EN60947-5-2 specifications | |||||
| Protection class | IP67 (EN 60529) (4) | |||||
| Connection cable | OW-TU20001(3) | OW-TU20002(3) | ||||
| Enclosure material | Stainless steel 316L | PBT | ||||
| Vibrating head material | Glass epoxy resin | |||||
| Torsional torque | Plastic enclosure: 1 N·m / Metal enclosure: 50 N·m | |||||
| Storage temperature | -35 to +70 °C (no freezing) | |||||
| Weight | 100 g | 70 g | ||||
| Model | NPN | TU-11N | TU-12N |
| PNP | TU-11P | TU-12P | |
| Main module/Expansion module | Main module | Expansion module | |
| Mounting method | DIN rail mounting | ||
| Type | Amplifier module | ||
| Power consumption | At 12 V: max. 1440 mW (120 mA); At 24 V: max. 1680 mW (70 mA) | ||
| Measurement value display | OLED | ||
| Display range | -9999 to 9999 | ||
| Display resolution | 1 mm/2 mm/3 mm/4 mm/6 mm | ||
| Sampling rate | 1,000 times/sec | ||
| Control input | No voltage input | ||
| Control output | HI/GO/LOW NPN/PNP open collector; 100 mA 30 V max; Residual voltage 1 V max; N.O./N.C. switchable | ||
| Response time | 1 ms | ||
| Communication method | RS-232 (can convert to RS-485 or USB output) | None*1 | |
| Main function | Current measured value display, original value display, upper limit/lower limit threshold manual setting, tolerance manual setting, upper limit/lower limit threshold automatic teach-in, tolerance automatic teach-in, display inversion, measurement plus or minus direction, preset value, peak hold, valley hold, peak-to-peak hold, initialization, key lock. | ||
| Calculation function | Maximum value, Minimum value, Peak-to-peak value, Average value, Reference deviation, Distortion value, Thickness, Warpage | None*2 | |
| Indicator | Output indicators: HIGH (red), GO (green), LOW (orange) | ||
| Rated supply voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less | ||
| Ambient temperature | -10 to +55 °C (no freezing) | ||
| Relative humidity | 35 to 85 % RH (no condensation) | ||
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | ||
| Connection method | Cable lead type (standard cable length 2 m) | ||
| Material | Main unit enclosure: Alloy aluminum; Membrane key switch: PET plastic; Cable: PVC | ||