| Main unit model | TU-H090 |
| Type | Diffuse reflective |
| Maximum sensing distance | 900 mm(2) |
| Minimum sensing distance | 100 mm |
| Sensing range | 100-900 mm |
| Beam angle | 10°±2° |
| Switching frequency (switching output) | 4 Hz |
| Response time (switching output) | 500 ms |
| Hysteresis | 1 % |
| Repeatability | 0.5 % |
| Resolution | ±2 mm |
| Linearity error | 1 % |
| Operating temperature range | -20 to +70 °C |
| Temperature compensation | Available |
| Thermal drift | ±2 % |
| Ripple coefficient | 5 % |
| Operating voltage | 12 to 24 VDC |
| Leakage current | 10 µA @ 30 VDC |
| Output voltage drop | 2.2 V max. (I = 100 mA) |
| No-load current | ≤50 mA |
| Output current (switching output) | 100 mA (3) |
| Minimum load resistance (analog voltage output) | 3 kΩ |
| Adjustable switching point | Teach-In button |
| Start-up delay | ≤300 ms |
| Indicator | Green: reflective; Yellow: output |
| Circuit protection | Short-circuit protection (automatic reset), inductive protection, reverse voltage protection |
| Electromagnetic compatibility/EMC | Conforms to the requirements of the EMC directive, in accordance with EN60947-5-2 specifications |
| Protection class | IP67 (EN 60529) (4) |
| Connection cable | OW-TU20001(3) |
| Enclosure material | Stainless steel 316L |
| Vibrating head material | Glass epoxy resin |
| Torsional torque | Plastic enclosure: 1 N·m / Metal enclosure: 50 N·m |
| Storage temperature | -35 to +70 °C (no freezing) |
| Weight | 100 g |
Quick Helpline