Model | PNP | TU-11P |
Main module/Expansion module | Main module | |
Mounting method | DIN rail mounting | |
Type | Amplifier module | |
Power consumption | At 12 V: max. 1440 mW (120 mA); At 24 V: max. 1680 mW (70 mA) | |
Measurement value display | OLED | |
Display range | -9999 to 9999 | |
Display resolution | 1 mm/2 mm/3 mm/4 mm/6 mm | |
Sampling rate | 1,000 times/sec | |
Control input | No voltage input | |
Control output | HI/GO/LOW NPN/PNP open collector; 100 mA 30 V max; Residual voltage 1 V max; N.O./N.C. switchable | |
Response time | 1 ms | |
Communication method | RS-232 (can convert to RS-485 or USB output) | |
Main function | Current measured value display, original value display, upper limit/lower limit threshold manual setting, tolerance manual setting, upper limit/lower limit threshold automatic teach-in, tolerance automatic teach-in, display inversion, measurement plus or minus direction, preset value, peak hold, valley hold, peak-to-peak hold, initialization, key lock. | |
Calculation function | Maximum value, Minimum value, Peak-to-peak value, Average value, Reference deviation, Distortion value, Thickness, Warpage | |
Indicator | Output indicators: HIGH (red), GO (green), LOW (orange) | |
Rated supply voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less | |
Ambient temperature | -10 to +55 °C (no freezing) | |
Relative humidity | 35 to 85 % RH (no condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Connection method | Cable lead type (standard cable length 2 m) | |
Material | Main unit enclosure: Alloy aluminum; Membrane key switch: PET plastic; Cable: PVC |