Model | TS-H600 | TS-H600L |
Temperature measurement range | -40 to +600 °C | |
Temperature measurement accuracy | ±1.5 % of reading or ±1.5 °C take the maximum value*¹ | |
Repeatability | ±0.5 °C of reading or ±1 °C take the maximum value*¹ | |
Spectral response | 8 to14 μm | |
Optical resolution D:S (90 %) | 15:1 | |
Temperature resolution | 0.1 °C | |
Response time (95 %) | 150 ms | |
Emissivity | 0.100 to 1.100 (software adjustable), preset 0.950 | |
Transmission rate | 0.100 to 1.100 (software adjustable), preset 1.000 | |
Display | 6-digit backlit LCD | |
Analog output | 4-wire 4 to 20 mA | |
Digital output | RS485 (supports Modbus RTU communication protocol) | |
Operating voltage | 24 VDC ± 20 % | |
Protection class | IP65 | |
Operating temperature |
Probe: -10 to +180 °C Controller: -10 to +70 °C |
Probe: -10 to +120 °C Controller: -10 to +70 °C |
Storage temperature | -20 to +80 °C | |
Operating humidity | 10 to 95 % (no condensation) | |
Cable withstand temperature |
Probe to electronics box: -20 to +200 °C Teflon Electronics box connection cable: -20 to +80 °C CPVC |
|
Cable length (probe to controller) | 3 m | |
Cable length (controller connection cable) | 0.5 m | |
Material | Probe: Stainless steel 304, Controller: Die-cast zinc alloy | |
Weight (standard cable length) | Probe: 40 g, Controller: 290 g |
Quick Helpline