| Model | TS-H600 |
| Temperature measurement range | -40 to +600 °C |
| Temperature measurement accuracy | ±1.5 % of reading or ±1.5 °C take the maximum value*¹ |
| Repeatability | ±0.5 °C of reading or ±1 °C take the maximum value*¹ |
| Spectral response | 8 to14 μm |
| Optical resolution D:S (90 %) | 15:1 |
| Temperature resolution | 0.1 °C |
| Response time (95 %) | 150 ms |
| Emissivity | 0.100 to 1.100 (software adjustable), preset 0.950 |
| Transmission rate | 0.100 to 1.100 (software adjustable), preset 1.000 |
| Display | 6-digit backlit LCD |
| Analog output | 4-wire 4 to 20 mA |
| Digital output | RS485 (supports Modbus RTU communication protocol) |
| Operating voltage | 24 VDC ± 20 % |
| Protection class | IP65 |
| Operating temperature | Probe: -10 to +180 °C Controller: -10 to +70 °C |
| Storage temperature | -20 to +80 °C |
| Operating humidity | 10 to 95 % (no condensation) |
| Cable withstand temperature | Probe to electronics box: -20 to +200 °C Teflon Electronics box connection cable: -20 to +80 °C CPVC |
| Cable length (probe to controller) | 3 m |
| Cable length (controller connection cable) | 0.5 m |
| Material | Probe: Stainless steel 304, Controller: Die-cast zinc alloy |
| Weight (standard cable length) | Probe: 40 g, Controller: 290 g |