| Model | LM-S1000P |
| Output type | PNP |
| Main module/Expansion module | Main module |
| Mounting method | DIN rail mounting |
| Type | Amplifier module |
| Power consumption | At 12 V: max. 1440 mW (120 mA); At 24 V: max. 1680 mW (70 mA) |
| Measurement value display | OLED |
| Display range | LM-S155 / LM-S050: -999.99 to 999.99; LM-S020: -99.999 to 99.999 |
| Minimum display unit | LM-S155 / LM-S050: 10 um; LM-S020: 1 um |
| Control input | No voltage input |
| Control output | HI/GO/LOW NPN/PNP open collector; 100 mA 30 V max; Residual voltage 1 V max; N.O./N.C. switchable |
| Response time | 200 μs |
| Communication method | RS-232 (can convert to RS-485 or USB output) |
| Main function | Current measured value display, original value display, upper limit/lower limit threshold manual setting, tolerance manual setting, upper limit/lower limit threshold automatic teach-in, tolerance automatic teach-in, display inversion, measurement plus or minus direction, zero drift value, peak hold, valley hold, peak-to-peak hold, initialization, key lock. |
| Calculation function | Maximum value, Minimum value, Peak-to-peak value, Average value, Reference deviation, Distortion value, Thickness, Warpage |
| Indicator | Output indicators: HIGH (red), GO (green), LOW (orange) |
| Rated supply voltage | 12 to 24 VDC, ripple (P-P) 10 % or less |
| Ambient temperature | -10 to +55 °C (no freezing) |
| Relative humidity | 35 to 85 % RH (no condensation) |
| Shock resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
| Connection method | Wire lead type (standard wire length 2 m) |
| Material | Main unit enclosure: Alloy aluminum; Membrane key switch: PET plastic; Cable: PVC |