Main unit model | Analog current | TU-N040A | TU-N090A | TU-N160A | TU-N220A | TU-N350A | TU-N600A |
Type | Diffuse reflective | ||||||
Maximum sensing distance | 400 mm(1) | 900 mm(2) | 1600 mm(2) | 2200 mm(2) | 3500 mm | 6000 mm(2) | |
Minimum sensing distance | 50 mm | 100 mm | 150 mm | 200 mm | 350 mm | 350 mm | |
Sensing range | 50-400 mm | 100-900 mm | 150-1600 mm | 200-2200 mm | 350-3500 mm | 350-6000 mm | |
Beam angle | 10°±2° | 15°±2° | 14°±2° | ±7° | ±9° | ||
Hysteresis | 1 % | ||||||
Repeatability | 0.5 % | 1 % | 0.5 % | ||||
Resolution | ±1 mm | ±2 mm | ±3 mm | ±4 mm | ±6 mm | ||
Linearity error | 1 % | ||||||
Operating temperature range | -20 to +70 °C | ||||||
Temperature compensation | Available | ||||||
Thermal drift | ±2 % | ||||||
Ripple coefficient | 5 % | ||||||
Operating voltage | 12 to 24 VDC | ||||||
Leakage current | 10 µA @ 30 VDC | ||||||
Output voltage drop | 2.2 V max. (I = 100 mA) | ||||||
No-load current | ≤50 mA | ||||||
Minimum load resistance (analog voltage output) |
3 k Ω | ||||||
Adjustable switching point | Teach-In button | ||||||
Start-up delay | ≤300 ms | ||||||
Indicator | Green: reflective; Yellow: output | ||||||
Circuit protection | Short-circuit protection (automatic reset), inductive protection, reverse voltage protection | ||||||
Electromagnetic compatibility/EMC | Conforms to the requirements of the EMC directive, in accordance with EN60947-5-2 specifications | ||||||
Protection class | IP67 (EN 60529) (4) | ||||||
Connection cable | Sold separately | ||||||
Enclosure material | Stainless steel 316L | PBT | |||||
Vibrating head material | Glass epoxy resin | ||||||
Torsional torque | Metal enclosure: 50 N·m | Plastic enclosure: 1 N·m | |||||
Storage temperature | -35 to +70 °C (no freezing) | ||||||
Weight | 100 g | 70 g |
Main unit model | Analog voltage | TU-N040V | TU-N090V | TU-N160V | TU-N220V | TU-N350V | TU-N600V |
Type | Diffuse reflective | ||||||
Maximum sensing distance | 400 mm(1) | 900 mm(2) | 1600 mm(2) | 2200 mm(2) | 3500 mm | 6000 mm(2) | |
Minimum sensing distance | 50 mm | 100 mm | 150 mm | 200 mm | 350 mm | 350 mm | |
Sensing range | 50-400 mm | 100-900 mm | 150-1600 mm | 200-2200 mm | 350-3500 mm | 350-6000 mm | |
Beam angle | 10°±2° | 15°±2° | 14°±2° | ±7° | ±9° | ||
Hysteresis | 1 % | ||||||
Repeatability | 0.5 % | 1 % | 0.5 % | ||||
Resolution | ±1 mm | ±2 mm | ±3 mm | ±4 mm | ±6 mm | ||
Linearity error | 1 % | ||||||
Operating temperature range | -20 to +70 °C | ||||||
Temperature compensation | Available | ||||||
Thermal drift | ±2 % | ||||||
Ripple coefficient | 5 % | ||||||
Operating voltage | 12 to 24 VDC | ||||||
Leakage current | 10 µA @ 30 VDC | ||||||
Output voltage drop | 2.2 V max. (I = 100 mA) | ||||||
No-load current | ≤50 mA | ||||||
Minimum load resistance (analog voltage output) |
3 k Ω | ||||||
Adjustable switching point | Teach-In button | ||||||
Start-up delay | ≤300 ms | ||||||
Indicator | Green: reflective; Yellow: output | ||||||
Circuit protection | Short-circuit protection (automatic reset), inductive protection, reverse voltage protection | ||||||
Electromagnetic compatibility/EMC | Conforms to the requirements of the EMC directive, in accordance with EN60947-5-2 specifications | ||||||
Protection class | IP67 (EN 60529) (4) | ||||||
Connection cable | Sold separately | ||||||
Enclosure material | Stainless steel 316L | PBT | |||||
Vibrating head material | Glass epoxy resin | ||||||
Torsional torque | Metal enclosure: 50 N·m | Plastic enclosure: 1 N·m | |||||
Storage temperature | -35 to +70 °C (no freezing) | ||||||
Weight | 100 g | 70 g |