| Model | IVS-H100 | |
| Installation distance | 90 to 110 mm | |
|
Detection range |
Zoom 6.4x to Zoom 1.0x | 5x5 mm to 32x32 mm |
| Digital zoom | 1.0–4.0x (17 stages) | |
| Light-receiving element | Black-and-white CMOS | |
| Light-emitting | Light source | Red LED (660 nm) |
| Lighting method | Pulsed illumination | |
| Indicator | 1 light (green/red/orange) | |
|
Environmental resistance |
Operating ambient temperature | -10 to +50 °C (no freezing) |
| Relative humidity | 35 to 85% RH (no condensation) | |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
| Shock resistance | 500 m/s² , 6 times in each of the X, Y, and Z directions | |
| Protection rating | IP67 | |
| Material |
Main housing: Zinc die-cast / PC, Cable: PVC, Operation indicator light: PMMA, Polarizing filter cassette: POM |
|
| Weight | Approx. 70 g | |
| Model | NPN/PNP | IVS-1000 | IVS-1050 |
| Mounting type | DIN rail mounting | ||
| Main module / Expansion module | Main module | Expansion module | |
| Detection mode | Presence Mode / Recognition Mode / Vibration Mode | ||
| Sensing head compatibility | Available | ||
| Response time | 3/10/20/50/100 ms | ||
| Display | Organic EL Display | ||
| Timer | OFF / OFF-Delay / ON-Delay / One-shot | ||
| Channel function | 4 channels | ||
| Other functions |
Filter, Direction Recognition, Anti-shake, Anti-interference, Viewfinder Display Orientation, Display Statistics, Key Lock,Input/Output Test, Response Difference |
||
| Control input | Type |
NPN: ON when connected to 0 V, OFF when connected to 24 V PNP: ON when connected to 24 V, OFF when connected to 0 V |
|
| Number of channels | 4 | ||
| Function | Channel Switching / Hold (Level) / Hold (Edge) / Light Emission Stop / Reset / External Tuning | ||
|
Control output*1 |
Type | Open collector, 50 mA max. (NPN/PNP; normally open/closed, switchable) | |
| Number of channels | 3 | ||
| Function | OK Output / NG Output / Trigger Output / Error Output | ||
| Power supply | Power voltage | 12 to 30 VDC, including ripple (P-P) 10% Class 2 or LPS | Power supply through the main unit |
|
Power consumption (without load) |
1950 mW or less (at 30 V, 65 mA max.) | 1800 mW or less (at 30 V, 65 mA max.) | |
|
Ambient resistance |
Operating ambient temperature |
-10 to +50 °C (no freezing) | |
|
Operating ambient humidity |
35 to 85 % RH (no condensation) | ||
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | ||
| Material | Housing | Polycarbonate | |
| Button | Polyacetal | ||
| Cable | PVC | ||
| Weight (including accessories) | Approx. 150 g | Approx. 150 g | |
|
* 1 When connecting expansion devices, the following restrictions apply depending on the number of connected units. When connecting 2 to 4 units (including the main unit): - Power supply voltage: 20 to 30 VDC - Control output current: Maximum 20 mA |
|||